EUROVENT certified and rated A++ for energy efficiency, Yamato heat pumps use a two-stage compressor and WILO fan and circulation pumps with Inverter technology, for high efficiency. They have a built-in expansion valve, a hydraulic kit that is built in (monobloc) or supplied with the unit (split), a touchscreen control panel and Wi-Fi control.

Capacity — 5 models in the series

Capacity
12kW
SEER / SCOP
- / 126.0
Min. sound pressure
29 dB(A)
Rated current
25.6 / 17.8 A
Cooling operation
10°C ~ 48°C
Power supply
230 / 50 / 1 - V / Hz / Ph

Code YHP12S1

Documentation

Manuals and useful documents

Technical specifications

Full data for this model

Model YHP12S1 · tolerance +/- 5%

Heating capacity, underfloor / fan coil or radiator 12.0 / 12.4 kW
Cooling capacity, underfloor / fan coil 11.0 / 10.6 kW
Declared load profile XL
Rated power input, heating / cooling 5.90 / 4.10 kW
Rated current, heating / cooling 25.6 / 17.8 A
Energy consumption, daily / annual 7.57 / 1589 kW
ESEER, cooling via underfloor / fan coil 7.15 / 4.90
Seasonal space heating efficiency (ηs), average climate, medium / low temperature 126 / 182 %
Water heating energy efficiency 105 %
COP, underfloor / fan coil or radiator 5.00 / 3.77 W/W
EER, underfloor / fan coil 4.4 / 2.79 W/W
Outdoor operating temperature range, cooling 10~48 ℃
Outdoor operating temperature range, heating -25~35 ℃
Outdoor operating temperature range, domestic hot water -25~45 ℃
Domestic hot water set temperature range 40~80 ℃
Supply water temperature, cooling, fan coil / underfloor 7 / 18 ℃
Supply water temperature, heating, fan coil / underfloor 45 / 35 ℃
Rated hot water temperature (outlet) 60 ℃
Power supply 230 / 50 / 1 V / Hz / Ph
Air flow volume 5015 m3/h
Sound pressure level, outdoor / indoor unit 55 / 29 dB(A)
Connection pipe outside diameter, liquid / gas φ6 / φ16 mm
Maximum refrigerant pipe length and height difference 15 m
Refrigerant R32
Refrigerant charge 1.84 kg
Outdoor unit net dimensions (L x W x H) 982 x 427 x 787 mm
Outdoor unit gross dimensions (L x W x H) 1097 x 478 x 937 mm
Indoor unit net dimensions (L x W x H) 860 x 460 x 318 mm
Indoor unit gross dimensions (L x W x H) 1133 x 568 x 390 mm
Outdoor unit net / gross weight 104 / 114 kg
Indoor unit net / gross weight 58 / 67 kg