Yamato Monobloc YHP08M1 8 kW heat pump
EUROVENT certified and rated A++ for energy efficiency, Yamato heat pumps use a two-stage compressor and WILO fan and circulation pumps with Inverter technology, for high efficiency. They have a built-in expansion valve, a hydraulic kit that is built in (monobloc) or supplied with the unit (split), a touchscreen control panel and Wi-Fi control.
Capacity — 5 models in the series
- 8kW YHP08M1
- 10kW YHP10M1
- 12kW YHP12M1
- 12kW 3Ph YHP12MT1
- 16kW 3Ph YHP16MT1
- Capacity
- 08kW
- SEER / SCOP
- - / 187.0
- Min. sound pressure
- 50 dB(A)
- Rated current
- 23.0 A / 12.0 A
- Cooling operation
- -15°C ~ 48°C
- Power supply
- 230 / 50 / 1 - V / Hz / Ph
Code YHP08M1
Documentation
Manuals and useful documents
-
Product brochure
-
Energy label
-
Energy label
Technical specifications
Full data for this model
Model YHP08M1 · tolerance +/- 5%
| Heating capacity, underfloor / fan coil or radiator | 8.2 / 8.3 kW |
|---|---|
| Cooling capacity, underfloor / fan coil | 8.3 / 7.4 kW |
| Declared load profile | XL |
| Power input, heating, underfloor / fan coil or radiator | 1.54 / 1.90 kW |
| Power input, cooling, underfloor / fan coil | 1.56 / 2.00 kW |
| Rated current, heating / cooling | 23.0 / 12.0 A |
| Energy consumption, daily / annual | 6.51 / 1358 kWh |
| Seasonal space heating efficiency (ηs), average climate, medium / low temperature | 146.0 / 187.0 % |
| Water heating energy efficiency | 123.35 % |
| COP, underfloor / fan coil or radiator | 5.32 / 4.32 W/W |
| EER, underfloor / fan coil | 5.32 / 3.70 W/W |
| Outdoor operating temperature range, cooling | -15~48 ℃ |
| Outdoor operating temperature range, heating | -25~35 ℃ |
| Outdoor operating temperature range, domestic hot water | -25~45 ℃ |
| Domestic hot water set temperature range | 40~80 ℃ |
| Supply water temperature, cooling, fan coil / underfloor | 5 / 18 ℃ |
| Supply water temperature, heating, fan coil / underfloor | 45 / 35 ℃ |
| Rated hot water temperature (outlet) | 65 ℃ |
| Power supply | 230 / 50 / 1 V / Hz / Ph |
| Sound pressure level | 50 dB(A) |
| Refrigerant | R32 |
| Refrigerant charge | 1.6 kg |
| Unit net dimensions (L x W x H) | 1206 x 445 x 878 mm |
| Unit gross dimensions (L x W x H) | 1338 x 553 x 1020 mm |