Yamato Split Heat Pump YHP16ST1 16kW, 3Ph

Product Code: YHP16ST1
  • EUROVENT Certification
  • Two-stage compressor
  • Control Wi-Fi
  • WILO Inverter Circulation Pump
  • Integrated expansion valve
  • Inverter DC fan motor
  • Touch screen control panel
  • Hydraulic kit integrated (monobloc)/included (split)
  • Energy class A++
Advantages
Integrated control panel
State-of-the-art components
Organic Refrigerant R32
Warranty Term: 3 years full
Other available capacities from the same range:
12000 BTU 18000 BTU 24000 BTU 42000 BTU
Reliability - Durability - Resistance

Technologies


Water temperature provided 60ºC

The patented two-stage DC Inverter compressor with EVI (Enhanced Vapor Injection) technology allows water to be heated to 60ºC, without electrical input, even at negative outdoor temperatures, with high efficiency.

Full protection

The equipment is equipped with several types of protection, such as: high/low pressure protection, overload protection, overheating protection or flow switch failure protection.

Safety lock

With this function, the operation of the control panel is locked to prevent accidental operation by children or persons unfamiliar with the operation of the equipment.

Complex control panel

The touch-screen control panel with backlighting allows simple and precise control of the heat pump. The selection of operating modes and functions (e.g. ACM priority, weekly and/or daily programming, Turbo, Silent, anti-ice function, self cleaning, fast hot water, underfloor heating, etc.) is very easy to use.

Useful materials


Smiley Face
Presentation Folder

Energy certificate


Technical Specs


General Features

Heating capacity floor / fan coil or radiator kW 15.5 / 16.3
Cooling capacity floor / fan coil kW 13.0 / 11.5
Declared load profile - XL
Rated power heating / cooling kW 7.97 / 5.88
Nominal current heating / cooling A 11.5 / 8.5
Annual daily energy consumption kWh 7.39 / 1542
ESEER underfloor cooling/fan convector - 6.79 / 4.64
SCOP medium climatic conditions medium / low temperature % 131 / 175
Energy efficiency water heating % 108
COP floor / fan coil or radiator W/W 4.51 / 3.88
EER floor / fan coil W/W 3.61 / 2.63
Outdoor operating temperature range cooling 10~48
Outdoor operating temperature range heating -25~35
Outdoor operating temperature range hot water -25~45
Set domestic water temperature range 40~80
Temperature of water supplied for cooling fan coil / floor 7 / 18
Temperature of water supplied for heating fan coil / floor 45 / 35
Nominal hot water temperature (outlet) 60
Power V / Hz / Ph 400 / 50 / 3
Air flow volume m3/h 5015
Sound pressure level outdoor / indoor unit dB(A) 58 / 29
Outside diameter of connecting pipe liquid / gas mm φ6 / φ16
Length and maximum height of refrigerated route m 15
Refrigerant - R32
Refrigerant quantity kg 1.84
Net/gross size of outdoor unit L x W x H mm 940 x 460 x 820
1103 x 573 x 973
Net/gross size of indoor unit L x W x H mm 860 x 460 x 318
1133 x 568 x 390
Weight outdoor unit net / gross kg 110 / 121
Weight of indoor unit net / gross kg 60 / 69